EEGLAB plugin importing Muse .csv recordings from the Mind Monitor, Muse Direct, and Muse Lab (OpenMuse) Apps. Compatible with Muse 1 (2014 & 2016), Muse 2, Muse S, and Muse S Athena (including the Athena's raw optical/fNIRS data). Data are automatically converted to the EEGLAB format, giving access to EEGLAB's tools (filtering, ICA, clean_rawdata, LIMO...).
Non-EEG channels (Accelerometer, Gyroscope, Photoplethysmogram, Auxiliary, and the Athena's optical fNIRS data) can be imported along with the EEG data.
Import menu: File → Import data → MUSE .csv file (from Mind Monitor or Muse Direct)
Optional signal selection dialog:
EEG = import_muse; % GUI: select a file and the optional signals
EEG = import_muse(filepath); % import EEG (command line)
EEG = import_muse(filepath, 'optics'); % EEG + Athena fNIRS optical data
EEG = import_muse(filepath, 'acc', 'gyr', 'aux', 'ppg'); % import everything
EEG = import_muse(filepath, 'detectBadChan'); % EEG + flag bad channels (reported, not removed)Supported file formats (auto-detected):
| Recording app | File layout | EEG | Extras |
|---|---|---|---|
| Mind Monitor (Muse 1/2/S) | TimeStamp + RAW_TP9... + band powers |
256 Hz | ACC, GYR, AUX |
| Muse Direct (Muse 1/2/S) | timestamps + eeg_1..6 + band powers |
256 Hz | ACC, GYR, PPG |
| Muse Direct (Muse S Athena) | Timestamp, PacketType, Data packets |
256 Hz | ACC, GYR, OPTICS (fNIRS) |
| Muse Lab / OpenMuse (Athena) | timestamp, osc_address, osc_type, osc_data |
256 Hz | ACC, GYR, OPTICS |
| Athena EEG export | ts, TP9, AF7, AF8, TP10 |
256 Hz | — |
| Athena optics export | ts, ch1..ch16 |
— | OPTICS only (64 Hz) |
Files containing only band power / session scores (no raw EEG) are rejected with a clear error message.
- Start EEGLAB, then import a file from the menu: File → Import data → MUSE .csv file (from Mind Monitor or Muse Direct); pick the optional signals in the dialog (or skip the dialog and use the command line below).
- Browse the imported data: Plot → Channel data (scroll). The 4 EEG channels (
TP9, AF7, AF8, TP10) plus any optional channels you selected (ACC, GYR, PPG, AUX, fNIRS optics) appear in the EEGLAB structure. - Preprocess as with any EEG dataset, e.g. filter 1–45 Hz (Tools → Filter data → Basic FIR filter; a 45 Hz low-pass keeps European 50 Hz line noise out of your analysis band), reject bad data automatically (Tools → Reject data using Clean Rawdata and ASR), or run ICA (Tools → Run ICA).
- Flag bad channels with the trained classifiers: import with
EEG = import_muse(filepath, 'detectBadChan');, or on an already imported EEG run[badChan, badChanLabels] = scan_channels(EEG, 0.5, 1);(see next section). - Analyze heart signals: if you imported the PPG channel (Muse 2/S recorded with Muse Direct) or recorded ECG separately, use the BrainBeats EEGLAB plugin to process heartbeat-evoked potentials (HEP), extract EEG and HRV features (SDNN, RMSSD, LF/HF power...), remove heart artifacts from the EEG, and compute brain-heart coherence: BrainBeats tutorial.
The Muse S Athena has a PPG/fNIRS optical sensor strip with 5 optodes over the left and right prefrontal cortex, recording at 64 Hz. Depending on the recording preset, the OPTICS packets contain 4, 8, or 16 data values per sample (wavelengths 730 nm, 850 nm, and red 660 nm, plus ambient-light readings). The plugin imports these values raw; when the full 16-value layout is present, channels are named by sensor position and wavelength (Mind Monitor mapping):
- 16 values:
LO_730, RO_730, LO_850, RO_850, LI_730, RI_730, LI_850, RI_850, LO_Red, RO_Red, LO_Amb, RO_Amb, LI_Red, RI_Red, LI_Amb, RI_Amb(LO/LI = left outer/inner sensor, RO/RI = right outer/inner; Amb = ambient light) - 8 values: inner + outer 730/850 nm
- 4 values: inner sensors only (
LI_730, RI_730, LI_850, RI_850) - Other layouts are imported as
Opt1...OptN
When imported together with the EEG with the 'optics' flag, optical channels are resampled (nearest-neighbor) onto the 256 Hz EEG time grid; optics-only files are returned at their native 64 Hz rate.
EEG = import_muse(filepath, 'detectBadChan');
% or, on an already imported (raw, unfiltered) EEG:
[badChan, badChanLabels] = scan_channels(EEG, 0.5, 1);The input EEG must be raw (no prior preprocessing); it is band-pass filtered 1-45 Hz on the fly (the training filter, with a 45 Hz low-pass that excludes European 50 Hz line noise) for classification (the output EEG remains raw). maxTol (second argument, default 0.5) is the portion of bad 5-s windows tolerated before a channel is flagged; with the default, up to half of the 5-s windows may be bad before the channel is flagged - set it lower (e.g. 0.33) to be stricter.
For each 5-s window, features are computed in the time, frequency, and nonlinear domains (RMS, SNR, low-frequency power, kurtosis, high-frequency power...), selected as most important by a Random Forest during model training.
I manually labeled 3,000 30-second EEG segments recorded with MUSE headsets as good or bad, and extracted features in the time, frequency, and nonlinear domains. I then trained an ensemble of machine learning models (decision trees, logistic regression, LDA, SVM, Naive Bayes, neural networks) with feature selection, PCA dimension reduction, hyperparameter tuning, and 5-fold cross-validation (on 80% of the data). The best model was validated on remaining data from 20% (different subjects, to avoid overfitting). The best models reached 93.5% accuracy for the frontal channels (logistic regression) and 91.4% for the posterior channels (decision tree). The classifiers are conservative: on clean recordings they can still flag a channel, so verify the results with scan_channels(EEG, maxTol, 1) (visualization on) when in doubt.
Flagged channels are reported, not removed automatically: check them visually (e.g. Plot > Channel data scroll; the classifiers run on the data band-pass filtered 1-45 Hz on the fly (the training filter, with a 45 Hz low-pass that excludes European 50 Hz line noise), the same filter as used for training), remove the channels you confirm are bad (e.g. EEG = pop_select(EEG, 'nochannel', {'AF7'});), and re-run or re-reference as needed.
Example output on a real rest recording (Muse IDL study): the AF7 channel (red, ~116 uV RMS after 1-45 Hz filtering) is flagged bad by the classifiers while the three low-RMS channels TP9 (7 uV), AF8 (4 uV), and TP10 (9 uV) are kept.
If you use this plugin, please cite the signal validation study:
Cannard, C., Wahbeh, H., & Delorme, A. (2021). Validating the wearable MUSE headset for EEG spectral analysis and Frontal Alpha Asymmetry. 2021 IEEE International Conference on Bioinformatics and Biomedicine (BIBM), 3603-3610. https://doi.org/10.1109/BIBM52615.2021.9669778
The study shows the MUSE can be used to examine power spectral density in all frequency bands, the individual alpha frequency, and frontal alpha asymmetry, with satisfying internal consistency reliability, compared to a research-grade 64-channel BIOSEMI system.
If this plugin does not work for you, see also this other independent implementation for importing Muse data.
- v2.2 - Muse S Athena support (packet, OSC log, EEG-only, and optics-only exports; 4/8/16 fNIRS optical channels); rewritten file parsing and sampling rate detection (fixed Mind Monitor rate errors); hour rollover support for legacy MindMonitor files; fixed command-line import crash, classifier output handling, bad-channel flagging with extra channels, and ACC/GYR amplitude scaling
- v2.1 - bug fixes
- v1.1 - added trained classifiers to flag bad channels
- v1.0 - Plugin created and available - June 7, 2021